Built-in electric motors

How to order

Induction motors of AV2K series

Induction motors of AV2K series are manufactured in accordance with technical specifications 16-513.506-81. Marine built-in three-phase squirrel-cage motors are designed for compressor and oil pump drives. Motors meet the requirements of GOST 183-74, GOST B 23396 and Terms of delivery ... No.1874-62. Motors are designed for three-phase AC power supply, 50Hz, 380V and 220V. Mounting arrangement is IM5010 in accordance with GOST 2479-79. Rated operating mode is continuous duty (S1) according to GOST 183-74. Cooling method is ICE (Fr) 37 for compressor drives and ICU37 for oil pump drives according to GOST 20459-87. Induction motors AV2K have a rated power range from 0.55 to 7.5 kW.


Induction motors of 3AVSH132 series

Induction motors of 3AVSh132 series are manufactured in accordance with technical specifications 16-525.569-84. Marine built-in three-phase squirrel-cage motors are designed for gastight compressor drives of electrochemical air revitalization.

Motors meet the requirements of GOST B 23396-78 and Terms of delivery ... No.01-1874-62. Motors are designed for three-phase AC power supply, 50Hz, 380V and 220V. Mounting arrangement is IM5010 in accordance with  GOST 2479-79. Rated operating mode is continuous duty (S1) according to GOST 183-74. Cooling method is ICW3741 according to GOST 20459-87. Induction motors 3AVSh132 have a rated power range from 5.5 to 7.5 kW.


Induction motors of 4AVSH132 series

Built-in three-phase squirrel-cage induction motors 4AVSh are manufactured in accordance with technical specifications 16-90. Motors are designed for compressor drives.

Motors meet the requirements of GOST B 23396-78 and Terms of delivery... No.01-1874-62.

Mounting arrangement is IM5010 in accordance with GOST 2479-79. Cooling method is ICW3741 in accordance with GOST 20459-87. Cooling of the motor in all operating modes is provided by machinery. Rated operating mode is continuous duty (S1) according to GOST 183-74. The number of start-ups per hour should not exceed 6 evenly distributed over time. Motors provide both left and right directions of rotation.


Induction motors of 3AV2K series

Induction motors of 3AV2K series are manufactured in accordance with technical specifications 16-525.570-84. Built-in three-phase squirrel-cage induction motors are designed for gastight freon compressor drives and oil pump drives of refrigerating machines. Motors meet the requirements of GOST B 23396-78 and Terms of delivery … No.01-1874-62. Motors are designed for three-phase AC power supply, 50Hz, 380V. Mounting arrangement is IM5010 in accordance with GOST 2479-79. Rated operating mode is continuous duty (S1) according to GOST 183-74. Cooling method of motors 3AV2K 1,5-6f, 3AV2K 2,2-6f, 3AV2K 2,2-4f, 3AV2K 4-4f for gastight freon compressor drives is ICE (Fr) 37; and of motors 3AV2K 1.5-4f and 3FV2K 2.2-4f for oil pump drives it is ICU37 according to GOST 20459-87.

Induction motors AV2K have a rated power range from 1.5 to 4.0 kW.


Built-in induction motors DAT 130-250-3

Built-in induction motors DAT 130-250-3 are manufactured in accordance with technical specifications 16513.513-82 and are designed for compressor drives KGBK and BSKA.

Motors are manufactured in accordance with GOST B 14000.0-78 and GOST B 14000.3-78. Motors are designed for 50Hz, 127V. Rated operating mode is according to GOST 183-74 SI, mounting arrangement is IM5010 in accordance with GOST 2479-79.

Motors can operate reliably in the following operating environments:

- halocarbon 12 GOST 19212-87 and oil KhF 12-16 GOST 5546-86

- halocarbon 22 GOST 8502-93 and oil KhF 22С-16 GOST 5546-86

- halocarbon 502 6-02-1200-84 and oil KhF 22С-16 GOST 5546-86


Induction motors of DAV80V2BN and DAV132BN  series

Built-in squirrel-cage induction motors DAV80V2BN and DAV132BN are of special design and manufactured in accordance with technical specifications of Ukraine 3.06 050-94. Motors are designed for submersible monoblock pumps TsMK, TsMF, GNOM, which pump feces fluid, domestic and industrial waste water. Motors meet the requirements of current technical specifications, GOST 183, DSTU 2365-94 and engineering documentation.  

Resistance of motors to external mechanical factors corresponds to mechanical design M6 in accordance with GOST 17516.1. Mounting arrangement is IM5010 in accordance with GOST 2479-79 (built-in, without a shaft and bearings). Motor's stator is mounted in a pump frame, and motor's rotor - on two bearing supports of the pump. Any mounting arrangement of the motor is available. Rated operating mode is continuous duty (S1) according to GOST 183. Cooling method is IC0040 according to GOST 20459.


Induction motors of AVSH100A2F and AVSH100V2F series

Induction motors AVSh100A2F and AVSh100V2F have universal marine low-magnetic configuration and are designed for oil pump drives of refrigerating compressors. Motors are manufactured in accordance with technical specifications 16-510.627-77. Motors are designed for operation in a sealed refrigerating system in halocarbon 12 GOST 19212-73, halocarbon 22 GOST 8502-73, refrigerator oils KhA-30 and KhF22-24 GOST 5546-66, KhS-40 technical specifications 38.40.151-73 with oil intake temperature max. 85°C. Motors meet the requirements of GOST 183-74 and Terms of delivery …No.01-1874-62, groups 23-24 of interdepartment standard HO.005.0 26.

Mounting arrangement is IM5010 in accordance with GOST 2479-79. Cooling method is ICU53 according to GOST 20459-75. Rated operating mode is continuous duty (S1) according to GOST 183-74. Motors are shock-resistant of grade I and vibration-resistant of grade A according to current rules and regulations No.063-76.4-001.  


Built-in induction motors of DAV112V4BD1 series

Built-in induction motors DAV112V4BD1 are manufactured in accordance with technical specifications 08-00213799-053-94. Motors are designed for sealed refrigerating compressor drives. Motors meet the requirements of current technical specifications, GOST 183, technical regulations on electromagnetic compatibility and engineering documentation.

Mounting arrangement is IM5010 in accordance with GOST 2479 (a stator's core with winding and a rotor without a shaft). Cooling method is ICE37 according to GOST 20459. Cooling of the motor in all operating modes is provided by a compressor.  

A motor incorporated in a compressor can operate reliably in halocarbon 22 according to GOST 8502 and in oil drops KhF22-24 or KhF22C-16 according to GOST 5546, KhS-40 according to technical specification 38.101763-82. Rated operating mode is continuous duty (S1) according to GOST 183. Mechanical design is M4 in accordance with GOST 17516.1. Motors provide both left and right directions of rotation.


Induction motor 2DMGKHM41-4

Induction motor 2DMGKhM41-4 is manufactured in accordance with technical specifications 16-89. Motors meet the requirements of GOST B 20.39.304-76.

Mounting arrangement is IM5010 in accordance with GOST 2479-79. Cooling method is ICE (Fr) 37 according to GOST 20459-87. Cooling of the motor in all operating modes is provided by a compressor. Motors can operate reliably in halocarbon 12 according to GOST 19212-87, halocarbon 22 according to GOST 8502-93, halocarbon 502 according to technical specification 6-02-1200-84 and in oil KhF22s-16 according to GOST 5546-86. Motors provide both left and right directions of rotation.  


Induction motors of AIV71-2BF2, AIV100-2BF2, AIV71-2F2 and AIV100-2F2 series

Induction motors AIV71-2BF2, AIV100-2BF2, AIV71-2F2 and AIV100-2F2 are manufactured in accordance with technical specifications 16-88. Motors are designed for sealed freon compressor drives. Motors meet the requirements of GOST 183-74, while motors AIV71V2BF2, AIV71V2F2, AIV71S2BF2, AIV71S2F2 and AIV71E2F2 additionally meet the requirements of GOST 160.510.065-90. Mounting arrangement is IM5010 in accordance with GOST 2479-79. Cooling method is ICE (Fr) 37 according to GOST 20459-87. Rated operating mode is continuous duty (S1) according to GOST 183-74. Motors provide both left and right directions of rotation.

Motors AIV100-2BF2 and AIV100-2F2 are designed for voltage of 220V and 380V with star connection diagram of rotors windings, 3 outputs, 50Hz. Single-phase motors AIVUE71 are designed for voltage of 220V, 50Hz and 60Hz.

Induction motors of DVK series

Three-phase squirrel-cage induction motors DVK are manufactured in accordance with technical specifications 16-513.476-80. Motors are designed for sealed refrigerating compressor drives. Motors meet the requirements of GOST 183-74.

Mounting arrangement is IM5010 in accordance with GOST 2479-79. Cooling method is ICE (Fr) 37 according to GOST 20459-87. Cooling of the motor in all operating modes is provided by a compressor. Rated operating mode is continuous duty (S1) according to GOST 183-74. Motors provide both left and right directions of rotation.



How to order
Contact us